Mocomtech CRS-300 Switch User Manual


 
CRS-300 1:10 Redundancy Switch Revision 16
Cables and Connections MN/CRS300.IOM
4–26
DB-9F connector labeled “1:1 Control” on the Traffic CDM-625(s).
Finally, for Balanced G.703 data only, connect and secure the Data Cable CA-0000072
(DB-15F to DB-9M, 6’) between the TMI(s) and Traffic CDM-625(s) as follows:
DB-15M connector labeled “P2” on the TMI(s), to
DB-9F connector labeled “Balanced G.703” on the Traffic CDM-625(s).
–or–
For Unbalanced G.703 data only, connect and secure the pair of PL/0813-8 cables (75
BNC to BNC, 8’) as follows:
BNC connector labeled “J3 Tx”on the TMI(s) to BNC connector labeled “Unbal
G.703/ASI – IN” on the Traffic CDM-625s, and
BNC connector labeled “J5 Rx”on the TMI(s) to BNC connector labeled “Unbal
G.703/ASI – OUT” on the Traffic CDM-625(s).
4.5.3.3 ASI Data Connections
If ASI is the driving traffic data type (refer to Figure 4-10 through Figure 4-12):
First,
connect the Control/Data Cable CA/WR0066 (for control purposes) between the Redundant
CDM-625 and the RMI (see
Sect. 4.5.3.1).
Next,
connect and secure a pair of PL/0813-8 cables (75 BNC to BNC, 8’), for data purposes,
between the Redundant CRS-625 and the RMI as follows:
BNC connector labeled “J3 Tx” on the RMI to BNC connector labeled “Unbal
G.703/ASI – IN” on the Redundant CDM-625, and
BNC connector labeled “J2 Rx” on the RMI to BNC connector labeled “Unbal
G.703/ASI – OUT” on the Redundant CDM-625.
Then, connect and secure a pair of PL/0813-8 cables (75 BNC to BNC, 8’) between the
CRS-325 TMI(s) and the Traffic CDM-625(s) as follows:
BNC connector labeled “J3 Tx” on the TMI(s), to BNC connector labeled “Unbal
G.703/ASI – IN” on the Traffic CDM-625(s), and
BNC connector labeled “J5 Rx”on the TMI(s) to BNC connector labeled “Unbal
G.703/ASI – OUT” on the Traffic CDM-625(s).
Finally, connect and secure the Control Cable CA-0000069 (HD-15M to DB-9M, 6’) between
the CRS-325 TMI(s) and Traffic CDM-625(s) as follows:
HD-15F connector labeled “J1” on the TMI(s), to
DB-9F connector labeled “1:1 Control” on the Traffic CDM-625(s).