1.6 Summary of Specifications
1.6.1 CRS-300 Specifications
Characteristic Requirement
Switch Type
1:N Redundancy Switch system ( N=10 max), Bridging architecture
C161 control processor
Compatible Modems
CDM-570/570L
CDM-600/600L
CDM-625
CDM-Qx/QxL
CDM-700
CDM-710
CDM-710G
SLM-5650/5650A
Operating Modes
Fully automatic or manual
Force traffic modem to redundant modem
Remove selected traffic modem from control
Programmable holdoff-to-backup and holdoff-to-restore (from 1 to 99 seconds)
Switching Conditions Switch to redundant modem following a Unit fault, Tx or Rx traffic faults
Switching Time 9 seconds max. (Delay interval set to minimum, 1 sec)
IF Switching
CRS-300 without CRS-280/280L IF Switch: IF ON / OFF control through the
Switch controller.
CRS-300 with CRS-280/280L: all modems outputs ON all the time.
Temperature
0 to +50°C (32 to 122°F) Operating
50 to 100°C (122 to 212°F) Storage
Humidity 95% at +40°C (104°F), Non-condensing
CE Mark EMC and Safety
Environmental
Operating temperature range: 0
°
to 40
°
C (32
°
to 104
°
F)
AC Prime Power Two independent inputs: 100 to 250 VAC, 50/60 Hz, at 25 watts VA max
DC Prime Power 48 (38 to 60) VDC 25 watts max
Redundant Modem
Signal Source
Any one of the 10 traffic paths (bridge mode) (both Rx IF and Tx data)
Front Panel
Vacuum Fluorescent Display (VFD): 2 lines @ 24 characters/line.
6-button Keypad: ENT (Enter), CLR (Clear), (4X) navigation
LED system status display showing, for all modems:
o Unit fault, Rx traffic fault
o Tx traffic alarm Online / Offline status
o Bridge status
Audible Alarm Programmable to activate following various changes of state
Common faults Dry relay contacts
Dimensional Envelope 19W x 11.75D x 6.75H inch (48.26W x 29.85D x 17.15H cm) (4RU)