National Instruments PC-DIO-96 Switch User Manual


 
Configuration and Installation Chapter 2
PC-DIO-96 User Manual 2-4 © National Instruments Corporation
Table 2-2. Switch Settings with Corresponding Base I/O Address and
Base I/O Address Space
Switch Setting Base I/O Address Base I/O Address
A9 A8 A7 A6 A5 (hex) Space Used (hex)
0 0 0 0 0 000 000 - 01F
0 0 0 0 1 020 020 - 03F
0 0 0 1 0 040 040 - 05F
0 0 0 1 1 060 060 - 07F
0 0 1 0 0 080 080 - 09F
0 0 1 0 1 0A0 0A0 - 0BF
0 0 1 1 0 0C0 0C0 - 0DF
0 0 1 1 1 0E0 0E0 - 0FF
0 1 0 0 0 100 100 - 11F
0 1 0 0 1 120 120 - 13F
0 1 0 1 0 140 140 - 15F
0 1 0 1 1 160 160 - 17F
0 1 1 0 0 180 180 - 19F
0 1 1 0 1 1A0 1A0 - 1BF
0 1 1 1 0 1C0 1C0 - 1DF
0 1 1 1 1 1E0 1E0 - 1FF
1 0 0 0 0 200 200 - 21F
1 0 0 0 1 220 220 - 23F
1 0 0 1 0 240 240 - 25F
1 0 0 1 1 260 260 - 27F
1 0 1 0 0 280 280 - 29F
1 0 1 0 1 2A0 2A0 - 2BF
1 0 1 1 0 2C0 2C0 - 2DF
1 0 1 1 1 2E0 2E0 - 2FF
1 1 0 0 0 300 300 - 31F
1 1 0 0 1 320 320 - 33F
1 1 0 1 0 340 340 - 35F
1 1 0 1 1 360 360 - 37F
1 1 1 0 0 380 380 - 39F
1 1 1 0 1 3A0 3A0 - 3BF
1 1 1 1 0 3C0 3C0 - 3DF
1 1 1 1 1 3E0 3E0 - 3FF
Note: Base I/O address values 000 through 0FF hex are reserved for system use.
Base I/O address values 100 through 3FF hex are available on the I/O
channel..