Nortel Networks 10BASE-T Switch User Manual


 
Installing the BayStack 410-24T Switch
309985-A Rev 00
2-3
Installation Procedure
This section provides the requirements and instructions for installing the
BayStack 410-24T switch on a flat surface or in a standard 19-inch utility rack. If
you install the switch in a rack, ground the rack to the same grounding electrode
used by the power service in the area. The ground path must be permanent and
must not exceed 1 ohm of resistance from the rack to the grounding electrode.
Installing the BayStack 410-24T Switch on a Flat Surface
Caution:
When this device is installed in a stack on a shelf or tabletop, the
accumulated weight of the port cables increases with the height of the shelf or
tabletop.
Achtung:
Wenn dieses Gerät in einem Stapel auf einem Tisch oder einem
Regalboden installiert wird, erhöht sich das Gesamtgewicht der
Schnittstellenkabel mit der Höhe des Regalbodens oder Tisches.
Attention:
Si l'appareil est posé dans un rack ou sur une étagère, notez bien
que le poids du câblage réseau augmente avec la hauteur de l'installation.
Precaución:
Cuando este dispositivo se instala apilado en un estante o sobre
una mesa, el peso acumulado de los cables de los puertos aumenta según la
altura del estante o de la mesa.
Attenzione:
Quando il dispositivo viene installato in stack su un ripiano o su
un tavolo, il peso dei cavi connessi alle porte aumenta in proporzione
all'altezza del ripiano o del tavolo.