Nortel Networks 10BASE-T Switch User Manual


 
Using the Console Interface
309985-A Rev 00
3-15
Table 3-4 describes the System Characteristics screen fields.
Table 3-4. System Characteristics Screen Fields
Field Description
Operation Mode
Read-only field that indicates the operation mode of the unit, for example:
When the unit is part of a stack configuration, the (read-only) field indicates the
unit is operational in a stack, and lists the current unit number of this switch. In
this example (see Figure 3-5
on page 3-14), the current unit number is Unit 2.
When the unit is
not
part of a stack configuration (operating standalone), the
read-only field indicates the unit is operating as a switch. When in this operation
mode, the Size of Stack and Base Unit fields (see following description) do not
appear.
Size of Stack
This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the number of units configured in the stack
configuration (1 to 8 units maximum).
Base Unit
This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the unit number of the switch that is currently
operating as the base unit.
MAC Address
The MAC address of the BayStack 410-24T switch or, when the switch is participating
in a stack configuration, the MAC address of the stack configuration.
Reset Count
A read-only field that indicates the number of resets since the operational firmware
was first loaded on the switch.
Default Value 1
Range 0 to 2
32
-1
Last Reset Type
A read-only field that indicates the last type of reset.
Default Value Power Cycle
Range Power Cycle, Software Download, Management Reset,
Management Factory Reset
Power Status
A read-only field that indicates the current power source (primary, RPSU, or both).
Default Value Primary Power
Range Primary Power, Redundant Power, Primary and Redundant Power
Local MDA Type
A read-only field that indicates the MDA type that is configured in this unit.
sysDescr
A read-only field that specifies the hardware and software version.
sysObjectID
A read-only field that provides a unique identification of the switch, which contains the
vendor’s private enterprise number.