LED Indications During the Download Process
The software download process automatically completes without user
intervention. The process erases the contents of flash memory and replaces it with
a new software image. Be careful not to interrupt the download process until after
it runs to completion (the process could take up to 10 minutes for completion,
depending on network conditions).
When the download process is complete, the switch automatically resets and the
new software image initiates a self-test. The BayStack 410-24T switch Self-Test
screen (see Figure 2-11 on page 2-15) briefly displays the results and is followed
by the Nortel Networks logo screen. Press [Ctrl]-Y from the Nortel Networks logo
screen to access the BayStack 410-24T switch main menu.
TFTP Server IP
Address
The IP address of your TFTP load host.
Default Value 0.0.0.0 (no IP address assigned)
Range Four-octet dotted-decimal notation, where each octet is represented
as a decimal value, separated by a decimal point
Start TFTP Load
of New Image
Specifies whether to start the download of the switch software image (default is No).
Use the spacebar to toggle the selection to Yes.
Press [Enter] to initiate the software download process.
Note:
The software download process can take up to 60 seconds to complete (or more
if the load host path is congested or there is a high volume of network traffic).
To ensure that the download process is not interrupted, do not power down the switch for
approximately 10 minutes.
Default Value No
Range Yes, No
Note:
If problems occur during the software download process, the Software
Download screen displays error codes that define the problem. The error codes
are described in Chapter 4, “Troubleshooting.”
Table 3-32. Software Download Screen Fields
(continued)
Field Description