Nortel Networks MSC8101 ADS Network Card User Manual


 
B-78 MSC8101ADS RevB User’s Manual MOTOROLA
A26 5V0 P +5V Supply. Connected to ADS’s 5V plane. Provided as power
supply for external tool. For allowed current draw, see TABLE 7-
1. "Off-Board Application Maximum Current Consumption"
on page 66
.
A27
A28
A29
A30
A31
A32
B1 GND P Digital Ground. Connected to main GND plane of the ADS.
B2
B3
B4 TSTAT0 I,P.U. Tool Status (0
a
:7). This lines may be driven by an external tool to
be read via BCSR2 of the ADS. These lines are pulled-up on the
ADS, by 10 K resistor’s network. See also
TABLE 7-1. "Off-
Board Application Maximum Current Consumption" on
page 66
.
B5 TSTAT1
B6 TSTAT2
B7 TSTAT3
B8 TSTAT4
B9 TSTAT5
B10 TSTAT6
B11 TSTAT7
B12 TOOLREV0 I,P.U. Tool Revision (0
a
:3). This lines should be driven by an external
tool with the Tool Revision Code, to be read via BCSR2 of the
ADS. These lines are pulled-up on the ADS, by 10 K resistor’s
network. See also
TABLE 5-12. "BCSR2 Description" on
page 58
.
B13 TOOLREV1
B14 TOOLREV2
B15 TOOLREV3
B16 EXTOLI0 I,P.U. External Tool Identification (0
a
:3). This lines should be driven by
an external tool with the Tool Identification Code, to be read via
BCSR2 of the ADS. These lines are pulled-up on the ADS, by 10
K resistor’s network. See also
TABLE 5-12. "BCSR2
Description" on page 58.
B17 EXTOLI1
B18 EXTOLI2
B19 EXTOLI3
B20 PORSTb I/O,P.U. Power-On-Reset. This line is connected to open drain output of
voltage detector device. When power-up is executed this line
asserted low during apr. 800 ms. Off-board power-on-reset may
be provided when this pin is driven by external O.D. (without pull-
up resistor) logic. Failure to do so might result in permanent
damage to the MSC8101 and / or to ADS logic.
TABLE B1-2. P1 - System Expansion - Interconnect Signals
Pin No. Signal Name Attribute Description
Frees
cale Semiconductor,
I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com
nc...