Nortel Networks 380-24F Switch User Manual


 
Chapter 4 Configuring the switch 75
Using Web-based Management for the BayStack 380-24F Gigabit Switch
2 In the port row of your choice, select from the lists.
3 Click Submit.
Configuring flow control
You can set switch port parameters for GBICs for flow control.
To configure flow control:
1 From the main menu, choose Configuration > Flow Control.
The Flow Control page opens (Figure 27).
Status (1) Enabled
(2) Disabled
Choose to enable or disable the port. You can also use this
field to control access to any switch port.
The default setting is Enabled.
Link The current link state of the corresponding port as follows:
Up: The port is connected and operational
Down: The port is not connected or is not operational.
Link/Trap (1) On
(2) Off
Choose to control whether link up/down traps are sent to the
configured trap sink from the switch.
The default setting is On.
Autonegotiation (1) Enabled
(2) Disabled
Choose to enable or disable the autonegotiation feature.
Choosing to enable autonegotiation sets the corresponding
port to match the best service provided by the connected
station.
The default setting is Enabled.
Speed / Duplex 1000Mbs / Full The default setting.
Table 26 Port Management page items
Item Range Description