Omron NT631C Printer User Manual


 
124
Connecting to the Host’s RS-422A/485 Port Section 5-2
*1
Crimp terminals of common use for M3 and M3.5
The terminal screws of the NT631/NT631C are M3.5 specification. When wir-
ing, use crimp terminals for M3.5 use. Tighten terminal screws with a tighten-
ing torque of 0.8 N
m.
The terminal screws of the RS-422A adaptor (CPM1-CIF11) are M3 specifica-
tion. When wiring, use crimp terminals for M3 use. Tighten terminal screws
with a tightening torque of 0.5 N
m.
Note 1. Make sure to tighten screws at the connectors after cable connection.
2. Always use crimp terminals for wiring at terminal blocks.
Examples of Applicable Terminals
For M3.5
•For M3
5-2-7 Setting the Terminal Resistance for RS-422A/485
Communications
The serial port B connector of the NT631/NT631C has a terminal resistance
setting terminal (TRM).
In RS-422A/485 communications, a terminal resistor must be set at the device
at the end of the communications cable, but not at any other device.
The NT631/NT631C has a built-in terminal resistor, and whether or not the
terminal resistance is applied is set by shorting or opening the terminal resis-
tance setting terminals (TRM). The terminal resistance is 120
.
When carrying out RS-422A/485 communications using serial port B, short
between terminals at the NT631/NT631C at the end of the RS-422A/485
cable. Leave these terminals open at NT631/NT631C PTs other than the one
at the end of the cable.
When not using RS-422A/485 communications, the terminal resistance set-
ting is ineffective.
Crimp ter-
minals
1.25-N3A
(fork type) *1
Japan Solderless
Terminal MFG
Recommended cable size:
AWG22 to 18
(0.3 to 0.75 mm
2
)
Y1.25-3.5L (fork
type) *1
Molex Inc.
Name Model Maker Remarks
Fork type
7 mm max.
Round type
7 mm max.
Fork type
6.2 mm max.
Round type
6.2 mm max.
RDA
TRM
RDB
SDA
Short-circuit tool