PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off
top and right edge. Left side of page extends to 9.25 inches.
Startup Screens
The following are sample screens that could occur
during the startup POST operation for normal
conditions and abnormal conditions:
STATUS : OK
MENU ENTER ESCAPE
STARTING DUAL-BUS
CONFIGURATION
MENU ENTER ESCAPE
Normal Screens
Startup Screen Status OK Screen
STATUS : HARDWARE
¸ ERROR
MENU ENTER ESCAPE
MENU ENTER ESCAPE
STATUS : HEAT
THRESHOLD EXCEEDED
Abnormal Screens
Temperature Exceeeded Screen Hardware Error Screen
If one of the errors occur during the startup, you will
have a continuous tone from the alarm and will need to
access the Component Status Menu to verify the
suspected failed component.
During normal operation, anytime one of the required
number of power supplies becomes inoperative, you will
receive a continuous alarm and a warning message will
appear. This message is simply a notification that the
state of the power supply system is no longer
redundant. Use the Component Status menu to
determine which power supply has failed and identify
the failed unit by absence of a “DC Good” LED on the
PSU. Replace the failed component returning the
system to a redundant state.