PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off
top and right edge. Left side of page extends to 9.25 inches.
Power Cord Selection
■
This subsystem is intended for indoor use only.
■
This subsystem is intended to be plugged into a 6A
branch circuit in Europe.
■
To select the proper power cord:
For 110 Volt Operation – Use a UL Listed/CSA Labeled
cord set consisting of a minimum 18 AWG, type SVT or
SJT three conductor cord, terminating in a molded
connector body having an IEC CEE-22 female
configuration on one end and a molded-on parallel
blade grounding type attachment plug rated 15A, 125V
configuration (5 - 15P) at the other end.
For 230 Volt Operation (North America) – Use a UL
Listed/CSA Labeled cord set consisting of a minimum
18 AWG, type SVT or SJT three conductor cord,
terminating in a molded connector body having an IEC
CEE-22 female configuration on one end and a molded-
on tandem blade grounding type attachment plug rated
15A, 250V configuration (6 - 15P) at the other end.
For 230 Volt Operation (Europe) – Use a cord set
marked “HAR”, consisting of a H05VV-F cord that has a
minimum 0.75 square mm diameter conductors
provided with an IEC 320 receptacle and a male plug
for the country of installation rated 6A, 250V.
Note: The subsystem automatically selects the proper
settings for the input voltage. Therefore, no additional
adjustments are necessary to connect the unit to any
input voltage within the range marked on the drive.
■
Das Laufwerk sollte nicht im Freien verwendet
werden.
■
In Europa, sollte das Laufwerk an einen 6A-
Stromkreis angeschlossen werden.
■
Zur Wahl des korrekten Netzkabels beachten Sie
bitte folgendes: