Packard Bell ST8000 Computer Drive User Manual


 
PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off
top and right edge. Left side of page extends to 9.25 inches.
JP3 (SCSI-to-SCSI IDs)
Caution:
Jumper configuration to be performed by
qualified service personnel only.
These jumpers (JP3) are used to manually set the SCSI-
TO-SCSI IDs for the SCSI-to-SCSI RAID controller. JP3
is an four position dual-row header.
JP3
1
S2S
SCSI
IDs
8
Jumper Positions
1 & 2 3 & 4 5 & 6 7 & 8 SCSI-to-SCSI ID Settings
ON ON ON ON 15
OFFONONON 14
ON OFF ON ON 13
OFF OFF ON ON 12
ON ON OFF ON 11
OFF ON OFF ON 10
ON OFF OFF ON 9
OFF OFF OFF ON 8
ON ON ON OFF 7
OFFONONOFF 6
ON OFF ON OFF 5
OFF OFF ON OFF 4
ON ON OFF OFF 3
OFF ON OFF OFF 2
ON OFF OFF OFF 1
OFF OFF OFF OFF 0
JP4 (SCSI ID Settings)
Caution:
Jumper configuration to be performed by
qualified service personnel only.