Rev.2.00 Nov 28, 2005 page 315 of 378
REJ09B0124-0200
M16C/6N Group (M16C/6NK, M16C/6NM) 22. Electric Characteristics (Normal-ver.)
Under development
This document is under development and its contents are subject to change.
Timing Requirements
(Referenced to VCC = 3.3V, VSS = 0V, at Topr = –40 to 85°C unless otherwise specified)
Table 22.31 Timer A Input (Counter Input in Event Counter Mode)
ns
ns
ns
TAiIN Input Cycle Time
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol
Parameter
Min.
Standard
Unit
Max.
150
60
60
Table 22.32 Timer A Input (Gating Input in Timer Mode)
tc(TA)
tw(TAH)
tw(TAL)
Table 22.33 Timer A Input (External Trigger Input in One-shot Timer Mode)
Table 22.34 Timer A Input (External Trigger Input in Pulse Width Modulation Mode)
Table 22.35 Timer A Input (Counter Increment/decrement Input in Event Counter Mode)
ns
ns
ns
TAiIN Input Cycle Time
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol
Parameter
Min.
Standard
Unit
Max.
600
300
300
t
c(TA)
tw(TAH)
tw(TAL)
ns
ns
ns
TAiIN Input Cycle Time
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol Parameter
Min.
Standard
Unit
Max.
300
150
150
t
c(TA)
tw(TAH)
tw(TAL)
ns
ns
TAiIN Input HIGH Pulse Width
TAiIN Input LOW Pulse Width
Symbol Parameter
Min.
Standard
Unit
Max.
150
150
t
w(TAH)
tw(TAL)
ns
ns
ns
ns
ns
TAiOUT Input Cycle Time
TAiOUT Input HIGH Pulse Width
TAiOUT Input LOW Pulse Width
TAiOUT Input Setup Time
TAiOUT Input Hold Time
Symbol Parameter
Min.
Standard
Unit
Max.
3000
1500
1500
600
600
t
c(UP)
tw(UPH)
tw(UPL)
tsu(UP-TIN)
th(TIN-UP)
Table 22.36 Timer A Input (Two-phase Pulse Input in Event Counter Mode)
µs
ns
ns
TAiIN Input Cycle Time
TAiOUT Input Setup Time
TAiIN Input Setup Time
Symbol
Parameter
Min.
Standard
Unit
Max.
2
500
500
t
c(TA)
tsu(TAIN-TAOUT)
tsu(TAOUT-TAIN)
VCC = 3.3V