Symbol Technologies MK1000 Scanner User Manual


 
3-44
MK1000 MicroKiosk Product Reference Guide
RS-485 Configuration Screen
From the Driver Configuration menu (see Figure 3-25 on page 3-39), press the Previous or
Next buttons to move the "<" cursor to either the RS-485 Port option and press the Enter
button. To return to the Driver Configuration menu, press the ‘1’ button to escape.
The RS-485 Config screen displays:
Figure 3-28. RS-485 Config Screen
The RS-485 Config screen includes the same structure and field definitions as the RS-232
Config screen with a slight difference: RS-485 includes extra Rx modes, and hardware
support exists for 10-bit and 11-bit serial frames (start bit, data bits, parity, stop bits) only.
Table 3-19. RS-485 Config Screen Definitions
Field Name Description
Baud Rate Press the Previous or Next buttons to move the "<"
cursor to this field and toggle by pressing the Enter
button to select the Baud Rate.
The default Baud Rate for MK1000 RS-485 port
settings is 9600.
Available Baud Rates: 110, 300, 600, 1200, 2400,
4800, 9600, 14400, 19200, or 38400.
RS-485 Config
Baud = 9600
Parity = NONE
Data = 8 BITS
Stops = 1 BIT
Flow = DTR/DSR
<
Echo = OFF
Rx = XPT