23
D14049.04
JULY 2008
Grey Headline (continued)
About Administrator Access
While it is possible to administer the
TANDBERG VCS via a PC connected directly
to the unit via a serial cable, you may wish to
access the system remotely over IP.
You can do this using either or both:
the
•
web interface via HTTPS
a
•
command line interface (CLI) via SSH or
Telnet.
By default, access via HTTPS and SSH is
enabled; access via Telnet is disabled. These
can be enabled and disabled according to your
requirements.
You can also enable access via HTTP.
However, this mode works by redirecting HTTP
calls to the HTTPS port, so HTTPS must be
enabled for access via HTTP.
!
Tandberg Management Suite (TMS)
accesses the VCS via the web server.
If HTTPS mode is turned off, TMS will
not be able to access it.
Overview
Security Considerations
To securely manage the VCS you should
disable Telnet, using the encrypted HTTPS and
SSH protocols instead. For further security,
disable HTTPS and SSH as well and use the
serial port to manage the system.
!
Because access to the serial port
allows the password to be reset, it is
recommended that you install the VCS
in a physically secure environment.
Conguring Administrator Access
To congure the ways in which your system is
accessed:
System Conguration > System
•
.
You will be taken to the System
Administration page.
In the Admin Access section, select Off or On
from the drop-down boxes for each service.
xConguration Administratio
•
n
Administration Accounts
The VCS has a default administrator account with full read/write access. This account is used
to log into the VCS via the web UI or the CLI. You can add additional administrator accounts with
either read/write access or read-only access; these can be used to log in via the web UI only. See
the Administration Accounts section for information on how to create these additional accounts.
Default Administrator Account
The default administrator account has a username of admin (all lower case) and a default password
of TANDBERG (all upper case). You cannot delete the default administrator account or change
the admin username, but you should change the password as soon as possible. Choose a strong
password, particularly if administration over IP is enabled.
Administrator Session Timeout
By default, Administrator sessions do not time
out – they remain active until you logout.
You can set the system to timeout an
Administrator session after a set number of
minutes of inactivity. The timeout period will
apply to all Administrator sessions using both
the Web Interface and the Command Line
Interface.
To set the timeout period:
System Conguration > System
•
.
You will be taken to the System
Administration page.
In the Admin Access section, in the Session
time out (minutes) box, enter the number
of minutes of inactivity after which an
administrator session should time out.
xConguration Administration
TimeOut
Values must be between 0 and 10,000. A
value of 0 means that Administrator sessions
will never time out.
Root Account
The VCS provides a root account which
will have the same password as the admin
account. The root account should not be used
in normal operation, and in particular system
conguration should not be conducted using
this account. Use the admin account instead.
You must restart the system for any
changes to the Administrator settings
to take effect.
!
It is possible to have more than one
Administrator session running at the
same time. These sessions could be
via the web interface, command line interface,
or a mixture of both. This may cause issues if
each Administrator session is attempting to
make the same conguration changes.
Changing the Default Administrator
Password
To change the administrator password:
Maintenance > Administration Accounts.
•
You will be taken to the Administration
Accounts page.
Click on View/Edit for the admin name.
You will be taken to the Edit Administration
Account page.
In the Password and Conrm Password elds,
enter the new password, and click Save.
To set an empty password via the web UI,
delete the characters from the Password and
Conrm Password elds and click Save.
xConguration SystemUnit Passwor
•
d
To set an empty password via the CLI, type:
xConguration SystemUnit Password: ""
Resetting the Default Administrator
Password
If you forget your password, it is possible to set
a new password using the following procedure:
Connect a PC to the VCS using the serial 1.
cable as per the instructions in steps 1 and
2 of Initial Conguration via Serial Cable.
Reboot the VCS.2.
Login from the PC with the username 3. pwrec.
No password is required.
You will be prompted for a new password.4.
The pwrec account is only active for one
minute following a restart. Beyond that
time you will have to restart the system
again to change the password.
TANDBERG VIDEO COMMUNICATIONS SERVER
ADMINISTRATOR GUIDE
Introduction Getting Started
Overview and
Status
System
Conguration
VCS
Conguration
Zones and
Neighbors
Call
Processing
Bandwidth
Control
Firewall
Traversal
Appendices
Applications Maintenance
System Administrator Access