TANDBERG MSE 8510 Computer Hardware User Manual


 
164
The events that are forwarded to the syslog receiver hosts are controlled by the event log capture filter.
To define a syslog server, simply enter its IP address and then click . The number of packets
sent to each configured host is displayed next to its IP address.
: Each event will have a severity indicator as follows:
0 - Emergency: system is unusable (unused by the MCU)
1 - Alert: action must be taken immediately (unused by the MCU)
2 - Critical: critical conditions (unused by the MCU)
3 - Error: error conditions (used by MCU error events)
4 - Warning: warning conditions (used by MCU warning events)
5 - Notice: normal but significant condition (used by MCU info events)
6 - Informational: informational messages (used by MCU trace events)
7 - Debug: debug-level messages (used by MCU detailed trace events)
If the MCU is being managed by a remote management system, for instance Tandberg TMS, information on that
remote system may be shown on this page. In certain circumstances you may need to remove the link between the
external system and the MCU using the "Clear" button here.