Component Testing
For accurate resistance and/or continuity checks, elec-
trically disconnect the component being tested from the
circuit (e.g. unplug the ignition switch connector before
doing a continuity check).
On/Off Switch
The on/off switch is used to shut the engine off. When
the on/off switch is in the off position, the engine arma
-
ture is grounded to prevent the engine from running.
This switch is located handle panel (Fig. 3).
Testing
In the OFF position, there should be continuity between
the two switch terminals. In the RUN position, there
should not be continuity between the two switch termi
-
nals.
1
Figure 3
1. On/Off switch
Figure 4
Electrical
System
Line Painter 1200 Page 4 – 5 Electrical System