22
1600XP Series Installation and Operation Manual
STANDARD MODELS: 14 – 22 KVA
Capacity 14 kVA (11.9 kW)
1
18 kVA (15.3 kW)
1
22 kVA (18.7 kW)
1, 5
General
Topology True On-Line
Certications
ANSI C62.41 (IEEE 587), UL 1778, CUL, CE, FCC Class A , NEC (NFPS-70),
NEMA/PE1-1993, OSHA, ASME, ISO 9001, ISO 14001:2004 , RoHS Compliant
Input Characteristics
Input Voltage
1
Single-phase, 208/240 VAC, +10% to –30%
1 1
Input Frequency 45-65 Hz (auto-sensing)
Input Capacity
14 kVA 18 kVA 22 kVA
Input /(Max Input) Current @208V
67.2 (68.9) A 86.4 (88.1) A 106 (107) A
Input /(Max Input) Current @240V
58.2 (59.7) A 74.9 (76.3) A 92.0 (93.0) A
Input Power Factor 0.98 Typical, 0.95 Minimum@ 100% Load
1
Current THD (linear load)
< 5%
Internal AC Input Breaker rating
100 A / 277 V 125 A / 277 V
Battery Characteristics
Battery Type Valve Regulated Lead Acid, Flame Retardant
Backup time, fully charged @ 0.7
power factor, 77 F
7 min.
2
5 min.
2
Backup time, fully charged @ 0.85
power factor, 77 F
7 min.
2
5 min.
2
3 min.
2
Recharge Time 24hr. (full), 12hr.(90%) for internal batteries only
3
Battery Voltage (Nominal) 288 VDC
Output Characteristics
Output Voltage Single-phase, 240/208/120 volts
Output Voltage Regulation = ±3%
Output Frequency ±0.5Hz/1.0Hz/1.5Hz (factory/authorized service center selectable only)
AUTO/MAN Frequency Factory or authorized service center selectable only
Voltage THD < 3% for linear load; < 6% for non-linear load
Common-Mode Noise < .5 Vrms
Rated Load Power Factor
1
0.85 (0.6 - 1.0) lagging
Efciency (AC-DC-AC) >86%
4
Voltage Transient < ±8% (Load of 0 to 100 %)
Voltage Transient Recovery 50 ms to within 2% of nominal
Rated Output Current (rms) 58 A 75 A 91.6 A
Max Peak Output Current 174 A 225 A 275 A
Inverter Overload Capacity 125%-30 sec./150%-10 sec
Bypass Overload Capacity 125%-10 min./1000%-1 cycle
Crest Factor 3.0
Input/output gures rated for 240 volts unless otherwise stated. Output ratings given for 0.85PF are only valid 1.
when the input voltage is greater than 204 volts; otherwise, ratings given for 0.70PF are applicable.
Battery 2. backup time may vary depending on the operating conditions and ambient temperature at the installation site.
An initial charge time of 24 hrs. is necessary to obtain proper battery performance level before unit is placed in operation.3.
Subject to update without notice.4.
Derate to 18.7 kVA (15.9 kW) for 50 Hz operation.5.