Toshiba 351C All in One Printer User Manual


 
© June 2005 TOSHIBA TECe-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 113
2
390CounterNumber of errors in HDD
(Copying)
PPC0
<8 digits>
SYSThe number of error is
reset at HDD format-
ting.
2
391CounterNumber of errors in HDD
(FAX)
FAX0
<8 digits>
SYS2
392CounterNumber of errors in HDD
(Scanning)
SCN0
<8 digits>
SYS2
393CounterNumber of errors in HDD
(Printer)
PRT0
<8 digits>
SYS2
398LaserNumber of polygonal motor
rotational speed switching
ALL0
<8 digits>
MCounts the number of
time the polygonal
motor has switched its
rotational speed
between normal rota-
tion and standby rota-
tion
2
399LaserAccumulated time of polyg-
onal motor at normal rota-
tion
ALL0
<8 digits>
MAccumulates the time
the polygonal motor has
rotated at normal rota-
tion.
2
400FuserFuser unit error status
counter
ALL0
<0-29>
M0: No error
1:C4112: C412
3:C4334:-
5: C4456: C446
7:C447 8: -
9: C449 10: C475
11: C47112: C472
13: - 14: -
15: C480 16: -
17: C49018: -
19: C44920: -
21: C44922: C449
23: C44924: C447
25: C44926: -
27: C44928: -
29: C449
1
409FuserFuser roller temperature at
a energy saver mode
(Center thermistor)
ALL13
<0-16>
M0: OFF 1:40°C
2: 45°C3: 50°C
4: 55°C 5:60°C
6: 65°C 7: 70°C
8: 75°C9: 80°C
10: 85°C 11: 90°C
12: 95°C 13: 100°C
14: 105°C15: 110°C
16:115°C
1
410-0FuserFuser roller temperature
during printing (Center
thermistor/Plain paper)
ALL
(black)
12
<0-16>
M0: 120°C1: 125°C
2: 13C3: 135°C
4: 140°C 5: 145°C
6: 150°C 7: 155°C
8: 16C9: 165°C
10: 170°C11: 175°C
12: 18C13: 185°C
14: 19C15: 195°C
16: 200°C
4
410-1FuserALL
(color)
11
<0-16>
M4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAMContents
Pro-
cedur
e