Toshiba 351C All in One Printer User Manual


 
e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE© June 2005 TOSHIBA TEC
2 - 114
411FuserFuser roller temperature on
standby (Center ther-
mistor)
ALL12
<0-16>
M0: 120°C1: 125°C
2: 13C3: 135°C
4: 14C5: 145°C
6: 15C7: 155°C
8: 16C9: 165°C
10: 170°C 11: 175°C
12: 18C 13: 185°C
14: 19C15: 195°C
16: 200°C
1
412-0FuserFuser roller temperature
during printing
(Center thermistor/Thick
paper 3)
ALL
(black)
12
<0-16>
M0: 120°C1: 125°C
2: 13C3: 135°C
4: 14C5: 145°C
6: 15C7: 155°C
8: 16C9: 165°C
10: 170°C11: 175°C
12: 18C 13: 185°C
14: 19C15: 195°C
16: 200°C
4
412-1ALL
(color)
12
<0-16>
M4
413-0FuserFuser roller temperature
during printing
(Center thermistor/Thick
paper 1)
ALL
(black)
12
<0-16>
M0:120°C1: 125°C
2:13C3: 135°C
4:14C 5: 145°C
6: 150°C 7: 155°C
8: 16C9: 165°C
10: 170°C11: 175°C
12: 18C13: 185°C
14: 19C15: 195°C
16: 200°C
4
413-1ALL
(color)
12
<0-16>
M4
415-0FuserPeriod of time retaining
print-start temperature
(Thick paper 3)
ALL
(black)
3
<0-10>
M0: Invalid 1: 1 sec.
2: 2 sec3: 3 sec
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec.9: 9 sec.
10: 10 sec.
4
415-1ALL
(color)
2
<0-10>
M4
416FuserTemperature setting to
start solving abnormality
(Center/Side thermistor/
Thick paper 3)
ALL9
<0-12>
M0: 120°C1: 125°C
2: 13C3: 135°C
4: 14C5: 145°C
6: 15C7: 155°C
8: 16C9: 165°C
10: 170°C11: 175°C
12: Invalid
1
417-0FuserPre-running time for first
printing (Thick paper 3)
ALL
(black)
16
<0-16>
M0: Invalid1: 0 sec.
2: 2 sec.3: 3 sec.
4: 4 sec.5: 5 sec.
6: 6 sec.7: 7 sec.
8: 8 sec.9: 10 sec.
10: 12 sec. 11: 14 sec.
12: 16 sec. 13: 18 sec.
14: 20 sec. 15: 25 sec.
16: 30 sec.
4
417-1ALL
(color)
0
<0-16>
M4
422FuserFuser roller temperature
setting at the end of pre-
running during warming-up
ALL4
<0-16>
M0: 120°C1: 125°C
2: 13C3: 135°C
4: 14C5: 145°C
6: 15C7: 155°C
8: 16C9: 165°C
10: 170°C11: 175°C
12: 18C13: 185°C
14: 19C15: 195°C
16: 200°C
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAMContents
Pro-
cedur
e