Toshiba 351C All in One Printer User Manual


 
e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE© June 2005 TOSHIBA TEC
2 - 94
258Mainte-
nance
FSMS acceptanceALL1
<0-2>
SYSSets whether the FSMS
connection is accepted
or not.
0: Prohibited
1: Accepted (serial
connection only)
2: Accepted (both
serial and USB con-
nections)
1
259NetworkStorage period at trail and
private
PRT14
<0-35>
SYS0:No limits
1 to 30: 1 to 30 days
31:1 hour
32:2 hours
33:4 hours
34:8 hours
35:12 hours
1
260NetworkWeb data retention periodALL10
<3 digits>
SYSWhen a certain period
of time has passed
without operation after
accessing TopAccess,
the data being regis-
tered is automatically
reset. This period is set
at this code.
(Unit: Minute)
1
263User
interface
Administrator's password
(Maximum 10 digits)
ALL123456
<10 dig-
its>
-The password can be
entered in alphabets
and figures (A-Z, a-z
and 0-9) within 10 dig-
its.
11
264NetworkFile retention periodALL30
<0-999>
SYS0: No limits
1 to 999: 1 to 999 days
1
265NetworkMaximum data capacity at
E-mailing
ALL30
<2-30>
SYS2 to 30 M bytes1
266NetworkMaximum data capacity at
Internet FAX
ALL30
<2-30>
SYS2 to 30 M bytes1
267Elec-
tronic
filing
Full guarantee of docu-
ments in Electronic Filing
when HDD is full
ALL1
<0-1>
SYSSets the file retention
level when editing the
files in the Electronic
Filing (at CutDoc/Save-
Doc command execu-
tion).
0: Not full retained
1: Fully retained
$ Retains the source
file until CutDoc/
SaveDoc command
is completed.
*The file is not
deleted even if the
HDD has become
full during the exe-
cution of command
when 1! is set.
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAMContents
Pro-
cedur
e
06/08