Toshiba B-EX4T1 Printer User Manual


 
APPENDIX 1 MESSAGES AND LEDS ENGLISH VERSION EO1-33089
APPENDIX 1 MESSAGES AND LEDS
EA1- 2
LED Indicatio
n
Printer Status
Restoration by
RESTART key
Acceptance of
Status Request/
Reset Command
No. LCD Message
ONLINE ERROR Yes/No Yes/No
21
POWER FAILURE
z
A power failure has occurred. No No
22
EEPROM ERROR
z
Data cannot be read from/written to a
backup EEPROM properly
No No
23
SYSTEM ERROR
z
When the following abnormal
operations are performed, a system
error occurs:
(a) Command fetch from an odd
address
(b) Access to word data at an odd
address
(c) Access to long-word data at an
odd address
(d) Access to the area of 80000000H
to FFFFFFFFH in the logic space
in user mode.
(e) An undefined instruction in an
area other than a delay slot was
decoded.
(f) An undefined instruction in a
delay slot was decoded.
(g) An instruction to rewrite a delay
slot was decoded.
No No
24
DHCP CLIENT
INITIALIZING…
z z
DHCP Client is being initialised. (Only
when the DHCP is enabled.)
----- -----
25
RFID WRITE ERROR
z
The printer did not succeed in writing
data onto an RFID tag after having
retried for a specified times.
Yes Yes
26
RFID ERROR
z
The printer cannot communicate with
the RFID module
Yes Yes
27
LOW BATTERY
z
The voltage of the Real Time Clock
Battery is low level.
No Yes
28
INPUT PASSWORD
z z
The printer is waiting for a password to
be entered.
No No
29
PASSWORD INVALID
Please Power OFF
z z
A wrong password was entered
consecutively for three times.
No No
NOTE: When an error message listed above appears on the LCD message display, please refer to Section 5