Unitech MS860 Barcode Reader User Manual


 
MS860 WiFi Manual
SCANNER CONFIGURATION MANAGER
RS232, continued
43
Receive Terminator
A user-definable Receive Terminator can be inserted at the end of
input data. Pre-defined receive terminators include:
The above special characters must be bracketed by < > symbols as
shown.
Function codes (F keys, cursor up, Enter, etc.) can also be inserted via
hexadecimal code (accessable in a linked menu) and must include
surrounding brackets (<>).
Letters and numbers should be entered directly by keyboard input
without surrounding brackets (<>).
Default is “None”.
<>>
z
> (greater than)
<<>
z
< (less than)
<dd>
z
Character in hexadeximal notation
<“>
z
(quotation marks)
<*>
z
Interblock Delay (data editing)
<a>
z
Any Letter (data editing)
<d>
z
Any Digit (data editing)
<n>
z
Line Feed
<r>
z
Carriage Return
<t>
z
Tab
BCC Character
Block Check Character. An error checking character added for data
integrity.
Default is “No”.
Time Out
The ACK/NAK function (see previous page) can be given a limited time
(from 1 to 10 seconds) or an unlimited time to operate.
Default is “1 Second”.
Data Direction
Three options are available for data direction:
Send to Host
Send to Host & Terminal
Send to Terminal
Default is “Send to Host”.