Specifications
A–2 445-0089-01-01
Electrical Specifications: Invert Mode
DC Input
Operating voltage range 10.0V–16.0V
Safe non-operating voltage range 0–18Vdc
Nominal current at full load 200A
AC Output
Output voltage 117Vac
Continuous power 2.0kW, 2.0kVA to 40°C max. ambient
Surge power 4.5kW for 5s
Max short-circuit current 55Arms, 55Apk
Frequency 60.0Hz ±0.05%
Wave shape Sine
THD (over load range of 0–2.0kW
resistive)
≤2%
Power derating above 40°C ambient temp See “Invert Power Derating vs. Ambient
Temperature” on page A–6.
Peak efficiency ≥87%
Full load efficiency ≥83%
Other
Load power factor range 0–1, inductive, capacitive, or nonlinear, to
2kVA
No load input power (producing output
voltage)
≤25W
Load sense power ≤4W (1s interval) ≤2W (3s interval)
Standby mode power draw
(no output, display off)
≤0.5W
Off mode current draw ≤2mA