Xantrex Technology PROsine 2.0 Projector User Manual


 
Configuration
4–12 445-0089-01-01
Configure Battery Menu
Menu Display
(if different from Menu Item)
Menu Items Access
Battery Size Installer
Dflt Batt Temp Default Batt Temp User
Battery Type Installer
View / Change Battery Details:
Batt Temp Coeff
Mode Settings: Bulk Charge
Bulk - Maximum Voltage
Bulk - Maximum Current (%C)
a
Bulk - Threshold Voltage
Bulk - Threshold Timeout
a.%C is used as the unit of measure for the current setpoints in the Configure Battery menu. The meaning of %C is as follows: Charg-
ing current generally varies with battery bank size. Therefore, current setpoints are generally expressed as %C where C is the ca-
pacity (Ah) of the battery bank. For example, to charge a 200Ah battery bank at 40A, a setting of 20% should be used.
View / Change Battery Details:
Battery Temp. Coefficient
Mode Settings: Bulk Charge
Max Voltage
Max Current (%C)
a
Threshold Voltage
Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Absorption Chrge
Absorption - Max Voltage
Absorption - Max Current (%C)
a
Absorption - Max Timeout
Absrptn - Threshld Current (%C)
a
Absrptn - Threshld Timeout
Mode Settings: Absorption
Max Voltage
Max Current (%C)
a
Max Timeout
Threshold Current (%C)
a
Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Overcharge
OverChg - Maximum Voltage
OverChg - Maximum Current (%C)
a
OverChg - Maximum Timeout
Mode Settings: Overcharge
Max Voltage
Max Current (%C)
a
Max Timeout
Installer
Installer
Installer
Mode Settings: Float
Float - Maximum Voltage
Float - Maximum Current (%C
a
)
Float - Maximum Timeout
Float - Threshold Voltage
Float - Threshold Timeout
Mode Settings: Float
Max Voltage
Max Current (%C
a
)
Max Timeout
Threshold Voltage
Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Equalize Charge
Equalize - Maximum Voltage
Equalize - Maximum Current (%C)
a
Equalize - Maximum Timeout
Equalize - Threshld Change
Equalize - Threshld Timeout
Mode Settings: Equalize
Max Voltage
Max Current (%C)
a
Max Timeout
Threshold Change
Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Constant Charge
Constant Voltage Setpoint
Constant Current Setpoint
Mode Settings: Constant
Voltage Setpoint
Current Setpoint
Installer
Installer
Charger Mode Charger Mode Installer
Charger Type Charger Type Installer
CHG Hi V Warning Offset Charger Hi V Warning Offset Installer