Configuration
4–8 445-0089-01-01
Configure PROsine—Advanced Menu
Menu Choices or Information Displayed
Load Sensing Select Enabled if you want the unit to periodically search for the presence of an
AC load while it is inverting. The unit will “sleep” if the load it detects is less than
the Load Sensing setting.
Select Disabled if you do not want the unit to search for an AC load.
For further information about load sensing, see “Load Sensing Mode” on page 5–
5.
Load Sense Power This setting determines what power the inverter needs to detect before it will start
automatically (if Load Sensing is Enabled). Settings range between 10 and
255W.
Load Sense Interval This is the amount of time between checks for the presence of an AC power load.
To save power while the unit is load sensing, increase the interval. The range is
0.5 to 25 seconds.
Menu Display
(if different from Menu Item)
Menu Items Access
Load Sensing User
Load Sense Power User
Load Sense Interval User
Low AC Transfer (V) User
Low AC Transfer (Hz) User
High AC Transfr (V) High AC Transfer (V) User
High AC Transfr (Hz) High AC Transfer (Hz) User
AC Series Mode Installer
Inverter Low V Shutdown User
Inverter Low V Warning User
INV Low V Restrt Hyst Inverter Low V Restart Hysteresis User
Run Without Panel User
Inverter After Reset (Without Panel) User
Charger After Reset (Without Panel) User
Auto Restart After Error User
Reset to Dflts Reset to Defaults Installer