Specifications
A–4 445-0089-01-01
Environmental Specifications
System
Regulatory Approvals
Ambient Temperature:
Operating Temperature Range
Storage Temperature Range
–20–60ºC, with output derated above 40
°C
–40–70ºC
Humidity: Operation/Storage 5–95% RH, non-condensing
Transfer relay rating 30A, 1.5hp
Transfer time 16ms
Transfer on bad voltage 85–110V for low AC and 120–135 for high AC,
user-adjustable.
Transfer on bad frequency 40–70Hz user-adjustable for high and low
frequency limits.
Inverter synchronized to line before
transfer
Yes
Remote ON/OFF An isolated input to the unit where, with 5–18V
applied the unit operates normally, with <1V the
unit is off.
Cooling Fan, activated by any of the following:
High internal temperature
High AC input current
High AC output current
CSA/NRTL approved to CSA 107.1, UL458 (including Marine Supplement), and UL1741
Complies with ABYC recommended practices E-8, E-9, A-20, and A-25 for marine use
Compliance to KKK-A-1822D for use in “Star-of-Life” ambulances available on request