Specifications
A–6 445-0089-01-01
Invert Power Derating vs. Ambient Temperature
If the unit is in elevated ambient temperature above 40°C, you are required to
reduce power draw according to the following chart to maintain regulatory
compliance and to avoid over-temperature shutdown.
PROsine Charger Output Current vs. AC Input Voltage
When the PROsine is charging batteries from a weak shorepower source the AC
voltage may fall as the PROsine draws current. To reduce the chance of the
shorepower voltage collapsing below the configured transfer level the PROsine
will reduce the charging current at low shorepower voltage according to the
following graph:
Inverter Output Power vs. Ambient
Temperature
0
500
1000
1500
2000
2500
-40-200 20406080
Ambient Temperature (°C)
Rated Continuous Outpu
t
Power (W)
Unit will run in
this area
Unit will run
in this area
Unit may shutdown in this area
Max Charge Current vs. Input AC Voltage
0
20
40
60
80
100
120
Input Vac (V rms)
Max Output Idc (A
)
Low Vac
Shutdown
Level
Low Vac
Shutdown + 2V
Low Vac
Shutdown + 6V
135Vac