Xerox 5101 All in One Printer User Manual


 
10 Main Menu
134 Wide Format Copy System User Guide
may also display as NO RESPONSE FROM SCANNER if the Scan System does not
process the request within the timeout period.
11. Press the
Enter key to return to the COMPONENT TESTS menu screen.
Sensors
Select the SENSORS option to display the current state of the Scan System optical paper
sensors, calibration home sensor, and the thick document sensor.
To display the status of the sensors:
1. Press the
Menu key. The MAIN MENU screen is displayed.
2. Press the
Next key until DIAGNOSTICS is highlighted.
3. Press the
Enter key to select DIAGNOSTICS. The DIAGNOSTICS menu screen is
displayed.
4. Press the
Next key until SCANNER DIAGNOSTICS is displayed.
5. Press the
Enter key to select SCANNER DIAGNOSTICS. The SCANNER
DIAGNOSTICS menu screen is displayed.
6. Press the
Next key until COMPONENT TESTS is highlighted.
7. Press the
Enter key to select COMPONENT TESTS. The COMPONENTS TESTS
menu screen is displayed.
8. Press the
Enter key to select SENSORS. Depending on the Document Feed-in Tray
configuration, a SENSORS screen is displayed. The screen below is with the
Productivity Tray. When a sensor is activated the icon
O is filled in.
SENSORS
INPUT: O
EXIT: O
HOME: O
REGISTER: O
THICK: O
O O O O O O O O O O
Sensors Screen
9. To check the status of the optical paper sensors:
a) Raise the Thickness Lever to enable an 8.5 X 11 sheet of paper to be inserted
into the Scan System.
b) Insert the sheet of paper centered on the Scan System and slowly push the
paper into the Scan System to check the INPUT, REGISTER, and EXIT sensors.
The sensors are located underneath the top cover. The photo below shows the
location of each of the sensors on the Document Feed Tray.