Cleaning the Calibration Strip
Perform the following steps monthly:
1. Press the
Menu key, then scroll to the Diagnostic and press the Enter key.
Scroll to CLEAN CAL ZONE and press the Enter key.
Press the Enter key to select CLEANING POSITION.
NOTE: The Top Cover must be closed while running this test.
2. Raise the Top Cover.
3. Inspect the Calibration Strip.
4. Place a small amount of platen glass cleaning fluid (Xerox 43P81) on a clean, lint-
free towel (600S4372) and clean the Calibration Strip.
5. Lower the Top Cover.
6. Press the
Enter key to select HOME POSITION.
7. Press the
Exit key to exit the CLEAN CAL ZONE.
8. Press the
Menu key to return to the READY screen. The Calibration Strip
automatically returns to its home position.