ADTRAN 810 Plus Network Card User Manual


 
Chapter 9. Dial Plan Terminal Menu
9-8 ATLAS 810
PLUS
User Manual 61200266L1-1
»» Data 56K, Data 64K,
Audio, Speech
Rejects outgoing calls based on call type. For example, setting the reject
number to $, Digital 56/64 to enabled, and Audio and Speech to disabled,
rejects all digital calls while not rejecting analog calls.
» Ifce Config
Sets configuration parameters for the endpoint. These parameters vary by
the type of port selected. For detailed information on the interface configu-
ration, see Interface Configurations on page 9-10.
>
GLOBAL
PARAM
Sets ATLAS options which apply to all switched operations, both incoming
and outgoing calls.
» End of Number
Timeout
Write security: 3; Read security: 5
Sets the length of time ATLAS waits before assuming the outgoing dialed
number is complete. The default value is six seconds. This timeout will only
be invoked if the dialed number does not match one of the patterns set in
the Number Complete Template menu (see Nbr Complete Templates below).
» Area Code
Write security: 3; Read security: 5
The local area code. Use for sending caller ID to the Network.
» Nbr Complete
Templates
Write security: 1; Read security: 5
Sets completed number patterns for outgoing calls so that ATLAS recog-
nizes when the phone number is complete. For example, a local number
will be 7 digits long while a long distance (1+ #) will be 11 digits long. The
ATLAS defaults cover almost any installation, and these templates should
not require any additional user input except for unusual circumstances.
The template allows the use of the following wild card inputs to define
numbers:
This list may remain blank if the Accept List meets desired filtering.
The Call Reject list takes precedence over the Call Accept list.
X
= Any single digit
N
= Any single digit 2—9
911
= This specific number
[1,2,3...]
= A single digit in this group