Chapter 7. Modules Terminal Menu
7-6 ATLAS 810
PLUS
User Manual 61200266L1-1
LCV
Line Code Violations.
PCV
Path Code Violations.
LES
Line Errored Seconds.
»» Performance: 15 Min
Write security:3; Read security:5
In the Performance 15 min. menu, the performance data for the previous 15
minute window is stored. Refer to Performance: Curr on page 7-5 for a
detailed description.
»» Performance: 24 Hr.
Write security:3; Read security:5
In the Performance 24 hr. menu, the performance data for the previous 24
hour window is stored. Refer to Performance: Curr on page 7-5 for a detailed
description.
»» Configuration
All of these configurable parameters depend on whether the port is connect-
ed to a Primary Rate ISDN circuit or a Channelized T1 circuit—dedicated or
switched.
Prt
Read security:5
Identifies the port number.
Port Name
Write security:3; Read security:5
Accepts any alphanumeric name up to 16 characters long to uniquely iden-
tify each port.
Frame
Write security:2; Read security:5
Matches the frame format of the circuit to which it is connected (available
from the network supplier).
Code
Write security:2; Read security:5
Matches the line code of the circuit to which it is connected (available from
the network supplier).
Tx Yellow
Write security:3; Read security:5
(Auto Tx Yellow Alarm) Enables and disables the transmitting of yellow
alarms.
Tx PRMs
Write security:3; Read security:5
(Transmit PRMs) Enables and disables the sending of PRM data on the facil-
ity data link (FDL). The PRM data continues to be collected even if Tx PRM
is disabled (possible only with ESF format).
LBO
Write security:2; Read security:5
(Line Build Out) Depends on whether the circuit is provisioned for DS1 by
the telephone company.
LB Accept
Write security:3; Read security:5
(Loopback Accept) Sets unit to accept or reject the in-band loop up and loop
down codes as defined in ANSI T1.403. This is a line loopback.