ADTRAN 810 Plus Network Card User Manual


 
Appendix A. System Event Logging
A-2 ATLAS 810
PLUS
User Manual 61200266L1-1
Table A-1. System Event
Event Category Console Log String
ATLAS configuration file loaded into the
system and activated
Critical System Configuration Uploaded
Console login failure
a
a. Three consecutive login attempts were attempted and failed.
Minor Login Failure
Internal system temperature has returned to
normal
Critical Internal Temperature Warning Cleared
Internal system temperature is too high Critical Internal Temperature Warning
Module found Info Module Found
Module removed or not responding Warning Module Not Responding
Primary power supply is present but is not
operating properly
Critical Main Power Supply Failure
SNMP authentication failure
b
b. Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP commu-
nities list but with a community name that does not match the community name defined in the SNMP communities
list.
Info SNMP Authentication Failure
System cold start
c
c. Generated five seconds after the completion of system initialization.
Normal Cold
The backup power supply is operating
properly or has been removed
Critical Backup Power Supply Failure Cleared
The backup power supply is present but is
not operating properly
Critical Backup Power Supply Failure
The primary power supply is operating
properly or has been removed
Critical Main Power Supply Failure Cleared
Table A-2. Switchboard Events
Event Category Console Log String
Call rejected
a
Warning <number> rejected: No such number
Call rejected
b
Normal <number> rejected: Outgoing reject list
Call rejected
c
Normal <number> rejected: Busy
Call successfully routed Normal <number> accepted: <slot> <port>
a. No such number in dial plan.
b. Number is on outgoing reject list.
c. All endpoints busy.