ADAM-5000 6-127
Chapter 6
#aaSi #aaSi
Example command: #16S2(cr)
response:
If the response you got is in Counter mode, you'll see
one similiar to the example below:
>1235458013267521306934521463051832106549(cr)
What you see here is actually the input values of all
channels that is returned from slot 2 of the ADAM-5000
system at address 16h.
As all 4 values are concatenated into one numerical
string such as above, we can still easily discern the
values of 4 channels specifically as:
1235458013, 2675213069, 3452146305 and
1832106549
If the response is
>0e88fa63c33697b52a68d61fe2ca6915(cr)
The command requests the module in slot 2 of the
ADAM-5000 system at address 16h to return the input
values of all channels.
The module response that input values if all channels
are hexdecimal:
0e88fa63,c33697b5,2a68d61f,e2ca6915