Redirect Policy Commands
destination
Syntax [no] destination ip-address
Context config>filter>redirect-policy
Description This command defines a cache server destination in a redirect policy. More than one destination can
be configured. Whether a destination IP address will receive redirected packets depends on the
effective priority value after evaluation.
Default none
Parameters ip-address — Specifies the IP address to send the redirected traffic.
ping-test
Syntax [no] ping-test
Context config>filter>destination>ping-test
config>filter>destination>snmp-test
Description This command configures parameters to perform connectivity ping tests to validate the ability for the
destination to receive redirected traffic.
Default none
drop-count
Syntax drop-count consecutive-failures [hold-down seconds]
no drop-count
Context config>filter>destination>ping-test
config>filter>destination>snmp-test
config>filter>destination>url-test
Description This command specifies the number of consecutive requests that must fail for the destination to be
declared unreachable.
Default drop-count 3 hold-down 0
Parameters consecutive-failures — Specifies the number of consecutive ping test failures before declaring the
destination down.