Alcatel-Lucent 7750 SR OS Network Router User Manual


 
Filter Policies
7750 SR OS Router Configuration Guide Page 423
Sample Output
A:ALA-A>config>filter# show filter redirect-policy
===============================================================================
Redirect Policies
===============================================================================
Redirect Policy Applied Description
-------------------------------------------------------------------------------
wccp Yes
redirect1 Yes New redirect info
redirect2 Yes Test test test test
===============================================================================
ALA-A>config>filter#
ALA-A>config>filter# show filter redirect-policy redirect1
===============================================================================
Redirect Policy
===============================================================================
Redirect Policy: redirect1 Applied : Yes
Description : New redirect info
Active Dest : 10.10.10.104
-------------------------------------------------------------------------------
Destination : 10.10.10.104
-------------------------------------------------------------------------------
Description : SNMP_to_104
Admin Priority : 105 Oper Priority: 105
Admin State : Up Oper State : Up
SNMP Test : SNMP-1
Interval : 30 Timeout : 1
Drop Count : 30
Hold Down : 120 Hold Remain : 0
Last Action at : None Taken
-------------------------------------------------------------------------------
Interval
Specifies the amount of time in seconds between consecutive requests
sent to the far end host.
Drop Count
Specifies the number of consecutive requests that must fail for the des-
tination to declared unreachable.
Hold Down
Specifies the amount of time in seconds that the system should be held
down if any of the test has marked it unreachable.
Hold Remain
Specifies the amount of time in seconds that the system will remain in
a hold down state before being used again.
Last Action at
Displays a time stamp of when this test received a response for a probe
that was sent out.
SNMP Test
Specifies the name of the SNMP test.
URL Test
Specifies the name of the URL test.
Label Description (Continued)