3. Procedure 100, Word 2 (for the digital side):
a. Enter the trunk group number (tgroup1) in Field 1.
b. Set the data rate for each speed optioned for the data modules in the modem pool in Fields 2
through 10.
NOTE
A data rate of 64 Kbps should always be translated for the modem pool in
addition to the data rates optioned on the data module; this will ensure that a
modem pool is selected when an incoming data call is directed to an AUDIX
DCP port. If 64 Kbps is not translated, the modem-pool setup may not work, or
may not recover after a failure.
c. Set Synchronous to 0 for asynchronous operation (Field 11 = 0).
d. Set Duplex to 0 for full duplex (Field 12 = 0).
e. Set Modem Pool Mode - Originate to 1 (Field 13 = 1).
f. Set Modem Pool Mode - Answer to 1 (Field 14 = 1).
g. Set Modem Pool - Modem Type to 1 (Field 15 = 1).
h. Set Modem Pool - Clock to 0 (Field 16 = 0).
i. Set Modem Pool - First Choice to 1 (Field 17 = 1).
j. Set Test Type to 0 (to turn off periodic on-line testing) or 1 (to allow periodic on-line testing)
(Field 18). Currently only R2V3 systems should have Field 18 set to 1. On other systems,
Field 18 should be 0.
k. Set Host Access Clock to 0 (Field 19 = 0).
_ ______________________________________________________________________________________
Wd 1 2-10 11 12 13 14 15 16 17 18 19 PROC
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
2 tgroup1 * 0 0 1 1 1 0 1 $ 0 100
_ ______________________________________________________________________________________
* = data rate (translate 64 Kbps in addition to optioned rates, usually 9600 bps)
$ = test type (see item j above)
4. Procedure 100, Word 1 (for the analog side):
a. Enter the trunk group number (tgroup2) in Field 1. A dial access code is not required (Fields 2
through 5).
b. Set Trunk Type to 101 (Field 6 = 101).
c. Set Dial Access Restriction to 0 (Field 7 = 0).
d. Set CO Line Appearance to 0 (Field 8 = 0).
_ ______________________________________________________________________________________
Wd 1 2 3 4 5 6 7 8 PROC
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
1 tgroup2 101 0 0 100
_ ______________________________________________________________________________________