AT&T 585-300-903 Network Router User Manual


 
AUDIX Network Testing 14-13
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
Step 1D: Testing Remote Dedicated RS-232 Connections
This test involves a path similar to Figure 14-11, Remote Connection Test (RS-232 Direct).
1. Go to the system : translation : machine : audix/amis/call delivery form.
Set machine name to the name of the other AUDIX system. Press ENTER . The other AUDIX
system’s machine profile should be displayed. If it is not displayed, it has not been assigned. Go to
Chapter 13, AUDIX System Administration, and create the remote system profile.
2. The network connection channel (or channel) should be set to the number of the channel that is
cabled to the other AUDIX system. In Figure 14-11, the AUDIX system 1 RS-232 channel 5 is a
switched connection and channel 6 is cabled to AUDIX system 2. The AUDIX system 2 profile at
AUDIX system 1 should have a 6 in the network connection channel field.
3. The network data phone number (or dial string) should be blank. Press CHANGE or RUN if any
changes were made.
4. Go to the maintenance : network form. Make sure the channel to be tested is idle.
5. Go to select test and enter 1.
6. Go to machine name and enter the name of the other AUDIX system. Press CHANGE or RUN . Wait
for the result. If the test is not successful, check the system : log and/or go to Flowcharts For
Troubleshooting the Network.