AT&T 585-300-903 Network Router User Manual


 
DCP Cabling and Administration 9-3
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
008D 008D
P
R
O
C
E
S
S
O
R
POWER
LEAVE THIS SLOT EMPTY
5 4 3
2 1 0
To reach this port
you dial *18
To reach this port
you dial *19
EXAMPLE:
SLOT
ID:
POWER
SUPPLY
SLOT
22
25
24
23
27
28
29
26
19
20
21
18
31
32
33
30
Figure 9-2. MERLIN II Default Configuration and Slot Assignments
2. At the rear of the AUDIX cabinet is a 25-pair female connector labeled ACC or ACCE. Connect the
25-pair male connector of the H600-331, Group 1 cable to this ACC connector. Or connect the 25-
pair male connector of a 356A adapter to this connector. Either setup will provide you with the two
D8W-87 female modular connectors required. The H600-331, Group 1 modular connectors should
have 451A adapters on the ends. Figure 9-3, AUDIX to MERLIN II Connectivity, shows a 356A
adapter being used.
3. Plug one end of a DW8-87 cord (male-male) into Jack No. 1 of the 356A adapter or Connector 1 of
the H600-331, Group 1 cable. If the AUDIX system is within 5 feet of the MERLIN II, the 451A
adapter can be removed from Connector 1, and Connector 1 (an D8W-87 male connector) can be
used in the next step.
Repeat this step with the second D8W-87 cord. Use Jack No. 2 of the 356A adapter or Connector 2
of the H600-331, Group 1 cable.