9-2 DCP Cabling and Administration
________________________________________________________________________________________________
________________________________________________________________________________________________
________________________________________________________________________________________________
SWITCH
PORTS
DCP
ED-1E434-11
GROUP 300
CROSS-CONNECT
FIELD
(OR GROUP 500)
A
B
25-PAIR MALE
CONNECTOR
ACC (OR ACCE)
25-PAIR FEMALE
CONNECTOR
H600-331, GROUP 2
AUDIX NETWORKING
BREAKOUT CABLE
AUDIX
DCP
RS-232C
RS-232C
Figure 9-1. DCP Cabling to the Switch Using the H600-331, Group 2 Cable
Non-DCP Switch Applications
The AUDIX DCP channels are connected directly to the MERLIN II using D8W-87 modular cords. The
installation of the MERLIN II Communications System is the responsibility of the customer or AT&T
General Business Systems. Thus, the following procedure requires a coordinated effort between them and
the AUDIX system installer. Make sure that the TN366B, TN539, or TN539B board is installed in the
AUDIX system and that the AUDIX system and MERLIN II are operational.
1. Assemble the system modules as shown in Figure 9-2, MERLIN II Default Configuration and Slot
Assignments, and power-on the MERLIN II system. The numbering of the jack positions will be the
default numbering shown on the 008D modules in Figure 9-2. If additional 008D modules need to be
added for additional ports, the numbering scheme continues to increase upward from bottom to top,
left to right as shown.