13-4 AUDIX System Administration
________________________________________________________________________________________________
________________________________________________________________________________________________
________________________________________________________________________________________________
DCORP STATUS: alarms: none, logins: 1, thresholds: none
PATH: system : translation : machine : audix/amis/call delivery
machine name: dcorp local/remote (l/r)? l password: setpace
extension length: 5 voice name (y/n)? _ voice id: 0 default community: __
network connection type: dcp data rate: 64000 channel: _
dial string: 62000
address ranges (prefix start / end extension) warnings
1: _____________________ 62001 / 63999
2: _____________________ 65000 / 65999
3: _____________________ 67000 / 67999
4: _____________________ __________ / __________
5: _____________________ __________ / __________
6: _____________________ __________ / __________
7: _____________________ __________ / __________
8: _____________________ __________ / __________
9: _____________________ __________ / __________
10: _____________________ __________ / __________
message transmission schedule (hh:mm) updates (y/n)? in _ out _
1. start: __:__ end: __:__ interval: __:__ network turnaround (y/n)? _
2. start: __:__ end: __:__ interval: __:__
3. start: __:__ end: __:__ interval: __:__ send to non-administered
new machine name: ______________ recipients (y/n)? _
Error and confirmation information appears on this line.
_ ______________________________ _ ____________________ _ ______________________________
CHANGE ADD DELETE HELP FIELD CLEAR EXIT ENTER
OR RUN
HELP
FORM
_ ______________________________ _ ____________________ _ ______________________________
Figure 13-1. Local AUDIX System Profile
NOTE
Use TAB to move to the next field. Use SHIFT-TAB to move to the previous field.
Use BACKSPACE to move back one space in a field.
Use RETURN while in a field to move back to the beginning of a field.
Overwrite all unwanted characters with the spacebar or with DEL CHAR.
Use the screen-labeled HELP keys for form and field information.
Form Fields
machine name
If this field does not display the machine name desired, press SHIFT and TAB at the same time to go
to new machine name. Enter the new name and press CHANGE or RUN . The new name will be
displayed in this field. After you log off and log back on, this name will also be displayed in the upper
left-hand corner of the AUDIX system screen.
If you change the name of the local AUDIX system and it is running R1V5 or later software, reset the
ACCE: access the maintenance : network form, enter a 5, and press CHANGE or RUN . If you
change the name of the local AUDIX system and it is running R1V3 or R1V4 software, restart the
AUDIX system via the startup form.
local/remote
This display-only field should show l, for local system.