Chapter 7
7-6 Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
ip dvmrp neighbor-probe-interval
Command Mode DVMRP Router Configuration.
Description Sets the DVMRP neighbor probe interval. Use the no form of this command
to return to the default value of 10 seconds.
Syntax
Sample Output The following example configures the IP DVMRP neighbor probe interval
for eleven seconds.
(configure router:dvmrp)# ip dvmrp neighbor-probe-interval
11
Systems P550R, P580, P880, and P882.
To Configure: ip dvmrp neighbor-probe-interval <neighbor-probe>
To Restore
Default:
[no] ip dvmrp neighbor-probe-interval
Table 7-4. Parameters, Keywords, Arguments
Name Definition
<neighbor-
probe>
The DVMRP neighbor probe interval, which is measured in
seconds. The valid range is 5-45 seconds. The default setting
is 10 seconds.