Document No. 10-300090, Issue 1 5-5
Console
set console initcmd
Command Mode Global Configuration.
Description Sets the modem initialization string for console serial port modem control
software. The default Modem Configuration String is AT&D0S0=1.
* Note: This command is not applicable when the console serial port is
configured in TTY mode. The input will not be accepted or
stored when the serial port is configured in TTY mode.
The init command string is used to configure the attached
external modem so that dial-in sessions will be properly
accepted by the modem and the connection successfully
completed between the switch and the remote system. The set
console initcmd is only accepted when the console serial port is
configured as PPP mode. Please read your modem’s reference
literature to find the correct AT parameters.
There are few configurations and Avaya recommended modems
that do not require a modem initialization string.
Syntax set console initcmd [init_cmd_string]
Sample Output The following example sets the console initialization command with an
initialization string of AT&D080=1
(configure)# set console initcmd AT&D0S0=1
Systems P550R, P580, P880, and P882.
Table 5-4. Parameters, Keywords, Arguments
Name Definition
[init_cmd_string] An optional parameter, however, when the parameter is
missing, it means that the modem initialization string is
<null>.