Setting the VLAN and diffserv parameters
Installing and Configuring the Avaya S8700-Series Server January 2008
61
14. Log back in to the IPSI using SSH.
15. Use show control interface to verify the administration.
16. Type exit and press Enter.
Setting the VLAN and diffserv parameters
1. Connect to the IPSIand log in as craft.
2. To display the quality of service values, type show qos and press Enter.
3. Use the set commands in the list below to set the VLAN, diffserv, and port parameters. If
the customer does not specify different values, use these recommended values.
Note:
Note: Use Help to obtain syntax guidelines for these commands.
!
Important:
Important: The settings for these parameters on the IPSIs must be consistent with the
settings on the servers and other network devices such as Ethernet switches.
● set vlan priority 6
● set diffserv 46
● set vlan tag on
● set port negotiation 1 disable
● set port duplex 1 full
● set port speed 1 100
4. Type show qos and press Enter to check the administered values.
5. Type reset and press Enter to capture the updated parameter values.
The reset terminates the administration session and automatically logs you out.
6. Log in again and use the show qos command to ensure that the parameter settings are
correct.
7. Disconnect the laptop from the IPSIfaceplate.
8. Check the LED on the IPSIfaceplate. Verify that the display shows the letters I and P and a
filled-in V at the bottom. (See Figure 6
).