Setting the VLAN and diffserv parameters
Installing and Configuring the Avaya S8700-Series Server January 2008
63
For the TN2312BP IPSI circuit packs to receive IP addresses dynamically, you first must assign
the switch ID and cabinet number to each IPSI circuit pack.The switch ID is a single letter, A
through J. The cabinet number is a 2-digit number, 01 through 64. For G650 Media Gateways, a
cabinet is defined as one or more media gateways connected by a TDM cable. This cabinet
configuration is called a G650-rack-mount-stack.
Note:
Note: In the following procedure, you must start step 2 within 5 seconds after inserting
the circuit pack.
1. Fully insert the TN2312BP IPSI circuit pack. If necessary, reseat the circuit pack to start
the programming sequence.
Note:
Note: For the following step, do not use a graphite pencil.
2. Insert a pen, golf tee, or similar object into the recessed push button switch.
Note:
Note: If you pass the letter or number that you want, you have two options. You can
cycle through all the letters or numbers to get to the one you want. Or, you can
reinsert, or reseat, the circuit pack and start again.
Note:
Note: If you have only one system, the default switch ID is A. The second system is B
and so on. The switch ID is not the media gateway or carrier letter.
CLK
S
E
R
V
fpdlled3 LJK 022502