Dell 6350 Server User Manual


 
1-14 Dell PowerEdge 6350 Systems Service Manual
1
Pin 13 — SYS_PS_ON# should measure between +4.75 and +5.25 VDC except when the
system is on, taking SYS_PS_ON# to its active-low state.
2
Pin 5 — SYS_PWR_GOOD should measure between +4.75 and +5.25 VDC when the power
supply is operating to indicate that all power-supply output voltages are within the ranges
specified in Table 1-2.
13 14 15 16 17
common (black)
+5 VL (red)
NC_TFSC (gray)
+5 VL (red)
SYS_PS_ON #
1
(gray)
common (black)
common (black)
common (black)
–5 VL (white)
+3.3 VL (orange)
18
+5 VL (red)
19 20 21 22 23 24
+5 VL (red)
12345
+12 VL (yellow)
+3.3 V_SENSE (orange)
common (black)
common (black)
+5 VFP (violet)
SYS_POWER_GOOD
2
(gray)
SENSE (black)
+5 V_SENSE (red)
common (black)
–12 VL (blue)
6
+5 VL (red)
789101112
+3.3 VL (orange)
1
PLANAR_ID (gray)
I2C_SCL_EXT (gray)
I2C_SDA_EXT (gray)
234567
+5 VL (red)
common (black)
+3.3 VL (orange)
12C_ALRT_EXT# (gray)
8
common (black)
+5 VL (red)
PRES_DET (gray)
91011121314
+12 VL (yellow)
common (black)
+5 VL (red)
common (black)