Dell 6350 Server User Manual


 
3-2 Dell PowerEdge 6350 Systems Service Manual
1-1-3 NVRAM write/read
failure
Replace the system board.
1-1-4 BIOS checksum
failure
Replace the system board.
1-2-1
1-2-2
1-2-3
Programmable
interval-timer failure
DMA initialization
failure
DMA page register
write/read failure
Replace the system board.
1-3-1 Main-memory
refresh verification
failure
Remove and reseat the DIMMs. If
the problem persists, replace the
memory module.
1-3-2 No memory installed Remove and reseat the DIMMs.
Reboot the system. If the problem
persists, replace the memory
module.
1-3-3
1-3-4
1-4-1
1-4-2
2-1-1
through
2-4-4
Chip or data line fail-
ure in the first 64 KB
of main memory
Odd/even logic fail-
ure in the first 64 KB
of main memory
Address line failure
in the first 64 KB of
main memory
Parity failure in the
first 64 KB of main
memory
Bit failure in the first
64 KB of main
memory
Remove and reseat the DIMMs.
Reboot the system. If the problem
persists, replace the memory
module.