Dell 6350 Server User Manual


 
Codes and Messages 3-7
Embedded
server
management
error
Embedded
server
management
is not
present
Embedded server
management
memory may be
temporarily
corrupted
Shut down the system to
clear the memory, and
then restart the system.
If the problem persists,
disconnect the AC power
cable for about 5 min-
utes and try again.
Gate A20
failure
Faulty keyboard
controller (defective
system board)
Replace the system
board.
General
failure
Operating system
corrupted or not
installed properly
Reinstall the operating
system.
Hard disk
drive read
failure
Hard disk
failure
Incorrect SCSI con-
figuration settings,
improperly con-
nected hard-disk
drive, faulty hard-
disk drive controller
subsystem, or loose
power cable
Check the primary and
secondary SCSI
configuration settings in
the SCSI configuration
utility. Reinstall the hard-
disk drive. Check the
interface cable and
power cable connections
to the backplane board.
If
the problem still persists,
replace the system
board.
Invalid con-
figuration
information -
please run
SETUP program
Incorrect ISA_CLR
jumper configura-
tion, incorrect
configuration set-
tings in System
Setup program, or
faulty battery
Remove the plug from
the ISA_CLR jumper.
Check the System Setup
configuration settings.
Replace the battery.
Invalid CPU
speed
detected -
check
jumpers
Incorrect micropro-
cessor jumper
configuration
Check the microproces-
sor speed jumper.
Invalid
NVRAM con-
figuration,
resource
reallocated
System detected
and corrected a
resource conflict
when system
resources were
allocated using the
RCU
No action is required.