EMC ED-12000B Switch User Manual


 
1
1-326
EMC Connectrix DS-32B2 and ED-12000B Fabric OS Reference Manual
Telnet Commands
portCfgSpeed
Configure the port speed level.
Syntax
portCfgSpeed [slotnumber/]portnumber, speed_level
Availability Admin
Description Use this command to configure the speed of a port to a particular
level. After this command is issued, the port is disabled and enabled
so that the port comes up with the new speed setting. The
configuration is saved in the nonvolatile memory and is persistent
across switch reboot or power cycle.
If the command is specified without an operand, you are prompted to
enter the speed value.
The output of the
portShow command displays the current achieved
speed of a port and the
portCfgShow command displays the user
desired speed setting for a port.
Operands This command has the following operands:
slotnumber
Specify the slot number in an ED-12000B switch.
The slot number must be followed by a slash ( / )
and the port number.
The ED-12000B has a total of 10 slots counted from
1 to 10. Slot number 5 and 6 are control processor
cards, and slot 1 through 4 and 7 through 10 are
switch cards. On each switch card, there are 16
ports counted from the bottom 0 to 15. A particular
port must be represented by both slot number (1
through 4 or 7 through 10) and port number (0
through 15).
This operand is not required for switches that do
not have blades.
portnumber
Specify the port number where you want to set the
speed. Valid values for number number vary
depending on the switch type. This operand is
required.