Emerson SAG581126000 Power Supply User Manual


 
System Application Guide SAG581126000
Spec. No. 581126000 (Model 700
NVBA) Issue AD, November 23, 2009
Page 105 of 123
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
1.3.10 MCA Display: The following are illustrations from the MCA Menu Tree (Section 6022).
Refer to the latest version of Section 6022 for the most recent MCA Menu Tree. Refer to the
"Navigating the MCA" and "System Operating Procedures" chapters of the Power System User
Instructions (Section 6013) for complete descriptions of menu items.
N
ET
S
URE™
MCA Menu Tree
(Sheet 1 of 2)
NORMAL DISPLAY W/ ALARMS
MAIN ALARM MENU
LVD ALARM MENU
PCU DETAIL MENU
1
## ALARMS ACTIVE
NOT RUNNING YET!
………………………….
STARTUP SEQUENCE
PCU ALARM MENU
134
SET ###V DEFAULTS
MUST SET SYS = ###V
LOADING ###V..##
26
PCU ** FAILURE
27
MAIN ALARM MENU
28
NORMAL DISPLAY
MCA ALARM MENU
47
PCU## EMERG STOP
48
PCU## AC FAIL
49
PCU## HI AC LINE
50
PCU## FAN FAIL
51
PCU## BRKR OFF
52
PCU## HVS ACTIVE
53
PCU## A/D FAIL
54
PCU## CONVERTER
55
PCU## HIGH TEMP.
56
PCU## OPEN SENSE
57
PCU## SWITCH OFF
58
PCU## NO REPLY
59
PCU ALARM MENU
60
NORMAL DISPLAY
NORMAL DISPLAY NO ALARMS
0
SYSTEM OK
NOTES:
1
Major Alarm
2
Minor Alarm
3
Minor Alarm = 1 PCU
Major Alarm = >1 PCU
4
Minor Alarm = A or B
Major Alarm = A and B
5
Minor Alarm = Sense Fuse
Major Alarm = System Fuse
6
## = Substitute appropriate number
8
7
** = Scroll through appropriate numbers
8
8
Applies to all menu items
9
Applies to all "Adjustable Settings"
10
All "Adjustable Settings" indicate changeable parameter
11
Exit to menu item 0 or 1 if all PCU serial #s match
12
Exit to menu item 0 or 1 if some PCU serial #s match
13
All "Normal" menu items lead to item 0 or 1
14
MCA P/N 534878 Only
Color Code
Initializing Normal Configuration Menu
Measurements
Adjustment Menu
Function
Adjustable Settings Alarms
Calibration Menu
22
LVD** ACTIVATED
23
24
MAIN ALARM MENU
25
NORMAL DISPLAY
Local Lockout On
9
ARE YOU SURE? +-
9
RECONNECT LVD**
29
MCA BOARD FAIL
1
30
A/D INPUT FUSE
5
31
NO SYSTEM VOLTS
1
32
NO SUBSYS VOLTS
1
33
NO SENSE VOLTS
2
SENSE VOLT ERROR
2
34
SHUNT** NO REPLY
2
SHUNT** BAD TYPE
2
34A
BAT CL INHIBITED
2
35
LVD** NO REPLY
1
LVD** EPROM FAIL
1
LVD** A/D FAILED
1
LVD** RELAY FAIL
1
LVD** NO MCA CMD
1
36
LVDs INHIBITED
2
37
REMOTE NO REPLY
2
38
DISPLAY NO REPLY
2
39
MAIN ALARM MENU
40
NORMAL DISPLAY
38A
TEMP** NO REPLY
1
TEMPERATURE ALARM MENU
28A
TEMP SENSOR** HI
28C
MAIN ALARM MENU
28D
NORMAL DISPLAY
28B
TEMP SENSOR** LO
2
ALARM EMERG STOP
1
3
ALARM LVD ACTIVE
4
4
5
6
7
8
ALARM SUBSYS LV
1
9
ALARM SUBSYS HV
1
10
ALARM SYSTEM FA
1
11
ALARM SUBSYS FA
1
12
ALM SUBSYS MAJOR
1
13
ALARM ALL AC OFF
1
14
ALARM HI AC LINE
3
15
16
ALM SYSTEM CURR
2
17
ALM SUBSYS CURR
2
17A
ALM BAT CHG CURR
2
18
ALM SUBSYS MINOR
2
19
ALARM MCA/SHELF
20
FUNCTION MENU
21
NORMAL DISPLAY
13
15A
ALM TEMP SENSOR
1
134A
SET ###### @ ###V
16
CHANGE SPEC...##
133
Initializing....##
11
MCA SWV ########
SPEC NO. ######
135 CHECK SETPOINTS!
12
136
FLOAT = ###.##V
137
138
139
139A
140
141
142
143
144
145
146
147
SUBCURR = #####A
147A
BAT CHG = #####A
148
LVD ** = ##.#V
149
LV RECON = ##.#V
MANUAL RECONNECT
150
ANALOG TC OFF
TC CAL = ##.##V
TempCmp Hardware
151
****A PLACES = ##
152
START THE SYSTEM
HI TEMP** = ###°C
HI TEMP** IS OFF
LO TEMP** = ###°C
LO TEMP** IS OFF
DIGITAL TC OFF
SLOPE = .###V/°C
TempCmp Hardware
MAX W/T = ##.##V
MIN W/T = ##.##V
TEST/EQ = ###.##V
SET HVS = ###.##V
CURRLIM = #####A
CURRLIM = #####MAX
BATTLIM DISABLED
BATTLIM = #####A
SYSCURR = #####A
SUB HV = ###.##V
SUB LV = ###.##V
to Sheet 2
150A
150B
150C
150D
150E
A
MUST SET SPEC NO.
15
MCA P/N 534871 Only
16
Press ACO/UP/DOWN simultaneously to reach this item.
ALM ## PCUs FAIL
3
ALARM MRFA
1,15
NO PCUs FOUND
1
ALARM 1 RFA
2,15
ALARM SYS 50%BOD
1
ALARM LO VOLTAGE
1,15
ALM VERY LO VOLT
1,14
ALARM SYSTEM BOD
1
ALARM LO FLOAT
1,15
ALARM SYSTEM HV1
1
ALARM HIGH FLOAT
1,15
ALARM SYSTEM HV2
1
ALARM HI VOLTAGE
1,15
INITIALIZATION MENU
SYS HV1 = ###.##V
HI FLOAT = ###.##V
15
SYS HV2 = ###.##V
HI VOLTAGE = ###.##V
15
SYS BOD = ###.##V
LOW FLOAT = ###.##V
15
SYS 50% = ###.##V
VERYLOVOLT = ###.##
14
LO VOLTAGE = ###.##
15
15B
ALM PCU## SHARE
1
Home